An examination of the electromyographic fatigue threshold test

David J. Pavlat, Terry J. Housh, Glen O. Johnson, Richard J. Schmidt, Joan Eckerson

Research output: Contribution to journalArticle

20 Citations (Scopus)

Abstract

The purpose of this investigation was to examine times to exhaustion at various percentages of the electromyographic fatigue threshold (EMGFT). Eight adult males [mean (SD), 21 (1) years] volunteered for the investigation. EMGFT was derived by determining the rate of rise in the electrical activity of the vastus lateralis [using integrated electromyography (iEMG)] over time (iEMG slope) for four fatiguing power outputs during cycle ergometry. The four power outputs were then plotted as a function of the four iEMG slope coefficients. The y-intercept of the power output versus iEMG slope coefficient graph was defined as the EMGFT. The intraclass correlation for repeated EMGFT tests was R=0.65 (SEE=7 W) and there was no significant (P>0.05) difference between the mean (SD) values for test [260 (11) W] versus retest [262 (32) W]. Actual times to exhaustion were determined for work bouts at power outputs equal to 85, 100, 115, 130, and 145% of EMGFT. The mean (SD) times to exhaustion for these work bouts were 495 (231), 225 (72), 135 (35), 94 (17), and 72 (14) s, respectively. A power curve was derived using the mean power outputs and mean times to exhaustion from the five rides at various percentages of EMGFT. The power curve provided estimates of the power outputs which could be maintained for 30 and 60 min. There were significant (PFT (260 W) and the power outputs which could be maintained for 30 (151 W) and 60 (125 W) min. EMGFT overpredicted the estimated power outputs that could be maintained for 30 and 60 min by 42% and 52%, respectively.

Original languageEnglish
Pages (from-to)305-308
Number of pages4
JournalEuropean Journal of Applied Physiology and Occupational Physiology
Volume67
Issue number4
DOIs
StatePublished - Oct 1993
Externally publishedYes

Fingerprint

Fatigue
Electromyography
Ergometry
Quadriceps Muscle

All Science Journal Classification (ASJC) codes

  • Public Health, Environmental and Occupational Health
  • Physiology

Cite this

An examination of the electromyographic fatigue threshold test. / Pavlat, David J.; Housh, Terry J.; Johnson, Glen O.; Schmidt, Richard J.; Eckerson, Joan.

In: European Journal of Applied Physiology and Occupational Physiology, Vol. 67, No. 4, 10.1993, p. 305-308.

Research output: Contribution to journalArticle

Pavlat, David J. ; Housh, Terry J. ; Johnson, Glen O. ; Schmidt, Richard J. ; Eckerson, Joan. / An examination of the electromyographic fatigue threshold test. In: European Journal of Applied Physiology and Occupational Physiology. 1993 ; Vol. 67, No. 4. pp. 305-308.
@article{d1f1b1c6beee44f7879ab06d33f32118,
title = "An examination of the electromyographic fatigue threshold test",
abstract = "The purpose of this investigation was to examine times to exhaustion at various percentages of the electromyographic fatigue threshold (EMGFT). Eight adult males [mean (SD), 21 (1) years] volunteered for the investigation. EMGFT was derived by determining the rate of rise in the electrical activity of the vastus lateralis [using integrated electromyography (iEMG)] over time (iEMG slope) for four fatiguing power outputs during cycle ergometry. The four power outputs were then plotted as a function of the four iEMG slope coefficients. The y-intercept of the power output versus iEMG slope coefficient graph was defined as the EMGFT. The intraclass correlation for repeated EMGFT tests was R=0.65 (SEE=7 W) and there was no significant (P>0.05) difference between the mean (SD) values for test [260 (11) W] versus retest [262 (32) W]. Actual times to exhaustion were determined for work bouts at power outputs equal to 85, 100, 115, 130, and 145{\%} of EMGFT. The mean (SD) times to exhaustion for these work bouts were 495 (231), 225 (72), 135 (35), 94 (17), and 72 (14) s, respectively. A power curve was derived using the mean power outputs and mean times to exhaustion from the five rides at various percentages of EMGFT. The power curve provided estimates of the power outputs which could be maintained for 30 and 60 min. There were significant (PFT (260 W) and the power outputs which could be maintained for 30 (151 W) and 60 (125 W) min. EMGFT overpredicted the estimated power outputs that could be maintained for 30 and 60 min by 42{\%} and 52{\%}, respectively.",
author = "Pavlat, {David J.} and Housh, {Terry J.} and Johnson, {Glen O.} and Schmidt, {Richard J.} and Joan Eckerson",
year = "1993",
month = "10",
doi = "10.1007/BF00357627",
language = "English",
volume = "67",
pages = "305--308",
journal = "European Journal of Applied Physiology",
issn = "1439-6319",
publisher = "Springer Verlag",
number = "4",

}

TY - JOUR

T1 - An examination of the electromyographic fatigue threshold test

AU - Pavlat, David J.

AU - Housh, Terry J.

AU - Johnson, Glen O.

AU - Schmidt, Richard J.

AU - Eckerson, Joan

PY - 1993/10

Y1 - 1993/10

N2 - The purpose of this investigation was to examine times to exhaustion at various percentages of the electromyographic fatigue threshold (EMGFT). Eight adult males [mean (SD), 21 (1) years] volunteered for the investigation. EMGFT was derived by determining the rate of rise in the electrical activity of the vastus lateralis [using integrated electromyography (iEMG)] over time (iEMG slope) for four fatiguing power outputs during cycle ergometry. The four power outputs were then plotted as a function of the four iEMG slope coefficients. The y-intercept of the power output versus iEMG slope coefficient graph was defined as the EMGFT. The intraclass correlation for repeated EMGFT tests was R=0.65 (SEE=7 W) and there was no significant (P>0.05) difference between the mean (SD) values for test [260 (11) W] versus retest [262 (32) W]. Actual times to exhaustion were determined for work bouts at power outputs equal to 85, 100, 115, 130, and 145% of EMGFT. The mean (SD) times to exhaustion for these work bouts were 495 (231), 225 (72), 135 (35), 94 (17), and 72 (14) s, respectively. A power curve was derived using the mean power outputs and mean times to exhaustion from the five rides at various percentages of EMGFT. The power curve provided estimates of the power outputs which could be maintained for 30 and 60 min. There were significant (PFT (260 W) and the power outputs which could be maintained for 30 (151 W) and 60 (125 W) min. EMGFT overpredicted the estimated power outputs that could be maintained for 30 and 60 min by 42% and 52%, respectively.

AB - The purpose of this investigation was to examine times to exhaustion at various percentages of the electromyographic fatigue threshold (EMGFT). Eight adult males [mean (SD), 21 (1) years] volunteered for the investigation. EMGFT was derived by determining the rate of rise in the electrical activity of the vastus lateralis [using integrated electromyography (iEMG)] over time (iEMG slope) for four fatiguing power outputs during cycle ergometry. The four power outputs were then plotted as a function of the four iEMG slope coefficients. The y-intercept of the power output versus iEMG slope coefficient graph was defined as the EMGFT. The intraclass correlation for repeated EMGFT tests was R=0.65 (SEE=7 W) and there was no significant (P>0.05) difference between the mean (SD) values for test [260 (11) W] versus retest [262 (32) W]. Actual times to exhaustion were determined for work bouts at power outputs equal to 85, 100, 115, 130, and 145% of EMGFT. The mean (SD) times to exhaustion for these work bouts were 495 (231), 225 (72), 135 (35), 94 (17), and 72 (14) s, respectively. A power curve was derived using the mean power outputs and mean times to exhaustion from the five rides at various percentages of EMGFT. The power curve provided estimates of the power outputs which could be maintained for 30 and 60 min. There were significant (PFT (260 W) and the power outputs which could be maintained for 30 (151 W) and 60 (125 W) min. EMGFT overpredicted the estimated power outputs that could be maintained for 30 and 60 min by 42% and 52%, respectively.

UR - http://www.scopus.com/inward/record.url?scp=0027426036&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027426036&partnerID=8YFLogxK

U2 - 10.1007/BF00357627

DO - 10.1007/BF00357627

M3 - Article

VL - 67

SP - 305

EP - 308

JO - European Journal of Applied Physiology

JF - European Journal of Applied Physiology

SN - 1439-6319

IS - 4

ER -