Bond strength, microleakage, and scanning electron microscopy examination of the Prisma Universal Bond 2 adhesive system.

Wayne W. Barkmeier, C. T. Huang, P. D. Hammesfahr, S. R. Jefferies

Research output: Contribution to journalArticle

11 Citations (Scopus)

Abstract

Dentin shear bond strength and marginal microleakage of a new primer/adhesive system were evaluated in this study and compared to Tenure Solution, Gluma, XR Primer/XR Bond, and Scotchbond 2. In addition, scanning electron microscopy examinations were conducted to evaluate the effect of the new primer on the smear layer, determine the film thickness of the primer/adhesive, and examine the resindentin interface of restorations placed with the new system.

Original languageEnglish
Pages (from-to)134-139
Number of pages6
JournalJournal of esthetic dentistry
Volume2
Issue number5
StatePublished - Sep 1990

Fingerprint

Adhesives
Electron Scanning Microscopy
Smear Layer
Shear Strength
Dentin
Prisma Universal Bond
XR Bond
Gluma
scotchbond 2

All Science Journal Classification (ASJC) codes

  • Medicine(all)

Cite this

Bond strength, microleakage, and scanning electron microscopy examination of the Prisma Universal Bond 2 adhesive system. / Barkmeier, Wayne W.; Huang, C. T.; Hammesfahr, P. D.; Jefferies, S. R.

In: Journal of esthetic dentistry, Vol. 2, No. 5, 09.1990, p. 134-139.

Research output: Contribution to journalArticle

@article{6e860521195c4d7d859b22b6f2ce09cf,
title = "Bond strength, microleakage, and scanning electron microscopy examination of the Prisma Universal Bond 2 adhesive system.",
abstract = "Dentin shear bond strength and marginal microleakage of a new primer/adhesive system were evaluated in this study and compared to Tenure Solution, Gluma, XR Primer/XR Bond, and Scotchbond 2. In addition, scanning electron microscopy examinations were conducted to evaluate the effect of the new primer on the smear layer, determine the film thickness of the primer/adhesive, and examine the resindentin interface of restorations placed with the new system.",
author = "Barkmeier, {Wayne W.} and Huang, {C. T.} and Hammesfahr, {P. D.} and Jefferies, {S. R.}",
year = "1990",
month = "9",
language = "English",
volume = "2",
pages = "134--139",
journal = "Journal of Esthetic and Restorative Dentistry",
issn = "1496-4155",
publisher = "Wiley-Blackwell",
number = "5",

}

TY - JOUR

T1 - Bond strength, microleakage, and scanning electron microscopy examination of the Prisma Universal Bond 2 adhesive system.

AU - Barkmeier, Wayne W.

AU - Huang, C. T.

AU - Hammesfahr, P. D.

AU - Jefferies, S. R.

PY - 1990/9

Y1 - 1990/9

N2 - Dentin shear bond strength and marginal microleakage of a new primer/adhesive system were evaluated in this study and compared to Tenure Solution, Gluma, XR Primer/XR Bond, and Scotchbond 2. In addition, scanning electron microscopy examinations were conducted to evaluate the effect of the new primer on the smear layer, determine the film thickness of the primer/adhesive, and examine the resindentin interface of restorations placed with the new system.

AB - Dentin shear bond strength and marginal microleakage of a new primer/adhesive system were evaluated in this study and compared to Tenure Solution, Gluma, XR Primer/XR Bond, and Scotchbond 2. In addition, scanning electron microscopy examinations were conducted to evaluate the effect of the new primer on the smear layer, determine the film thickness of the primer/adhesive, and examine the resindentin interface of restorations placed with the new system.

UR - http://www.scopus.com/inward/record.url?scp=0025494982&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0025494982&partnerID=8YFLogxK

M3 - Article

C2 - 2129406

AN - SCOPUS:0025494982

VL - 2

SP - 134

EP - 139

JO - Journal of Esthetic and Restorative Dentistry

JF - Journal of Esthetic and Restorative Dentistry

SN - 1496-4155

IS - 5

ER -