Decreasing radiation exposure in pediatric trauma related to cervical spine clearance

A quality improvement project

Valerie Ann Waddell, Susan Connelly

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Study Design: Quality improvement project. Objectives: Reduce the amount of radiation exposure in the pediatric trauma population 5 years of age and older in relation to cervical spine clearance. Background: The evaluation of pediatric cervical spine injuries must be accurate and timely to avoid missed injuries. The difficult clinical examination in pediatric trauma patients necessitates the use of radiologic examinations to avoid missing catastrophic injuries. However, exposure to radiation at an early age increases the pediatric patients' risk of developing cancer (R. A. Kleinerman, 2006). Methods: A retrospective chart review was conducted to assess radiation exposure in pediatric patients requiring evaluation for cervical spine clearance. Surgical staff and emergency department physicians received education on the risks related to pediatric radiation exposure and information related to the institution's diagnostic trends for cervical spine clearance. An algorithm was then developed to assist with determining the necessary imaging study for cervical spine clearance. Radiation exposure was monitored following initial education and use of the algorithm to determine its effect on radiation exposure. Results: The retrospective chart review identified cervical spine computed tomography (CT) in 34%, with an average radiation exposure of 3.5 mSv. Following education and introduction of an algorithm, 18% of patients underwent CT for cervical spine clearance with an average radiation exposure of 3.2 mSv, representing a 47% decrease in the use of CT. Conclusion: Staff education and the use of an algorithm show promise in the reduction of radiation exposure and provide safe, effective clearance of the cervical spine in pediatric trauma.

Original languageEnglish (US)
Pages (from-to)38-44
Number of pages7
JournalJournal of Trauma Nursing
Volume25
Issue number1
DOIs
StatePublished - Jan 1 2018

Fingerprint

Quality Improvement
Spine
Pediatrics
Wounds and Injuries
Education
Tomography
Radiation Exposure
Hospital Emergency Service
Physicians

All Science Journal Classification (ASJC) codes

  • Emergency
  • Critical Care
  • Advanced and Specialized Nursing

Cite this

Decreasing radiation exposure in pediatric trauma related to cervical spine clearance : A quality improvement project. / Waddell, Valerie Ann; Connelly, Susan.

In: Journal of Trauma Nursing, Vol. 25, No. 1, 01.01.2018, p. 38-44.

Research output: Contribution to journalArticle

@article{842682c924d74ae8a71602fecc543a34,
title = "Decreasing radiation exposure in pediatric trauma related to cervical spine clearance: A quality improvement project",
abstract = "Study Design: Quality improvement project. Objectives: Reduce the amount of radiation exposure in the pediatric trauma population 5 years of age and older in relation to cervical spine clearance. Background: The evaluation of pediatric cervical spine injuries must be accurate and timely to avoid missed injuries. The difficult clinical examination in pediatric trauma patients necessitates the use of radiologic examinations to avoid missing catastrophic injuries. However, exposure to radiation at an early age increases the pediatric patients' risk of developing cancer (R. A. Kleinerman, 2006). Methods: A retrospective chart review was conducted to assess radiation exposure in pediatric patients requiring evaluation for cervical spine clearance. Surgical staff and emergency department physicians received education on the risks related to pediatric radiation exposure and information related to the institution's diagnostic trends for cervical spine clearance. An algorithm was then developed to assist with determining the necessary imaging study for cervical spine clearance. Radiation exposure was monitored following initial education and use of the algorithm to determine its effect on radiation exposure. Results: The retrospective chart review identified cervical spine computed tomography (CT) in 34{\%}, with an average radiation exposure of 3.5 mSv. Following education and introduction of an algorithm, 18{\%} of patients underwent CT for cervical spine clearance with an average radiation exposure of 3.2 mSv, representing a 47{\%} decrease in the use of CT. Conclusion: Staff education and the use of an algorithm show promise in the reduction of radiation exposure and provide safe, effective clearance of the cervical spine in pediatric trauma.",
author = "Waddell, {Valerie Ann} and Susan Connelly",
year = "2018",
month = "1",
day = "1",
doi = "10.1097/JTN.0000000000000340",
language = "English (US)",
volume = "25",
pages = "38--44",
journal = "Journal of trauma nursing : the official journal of the Society of Trauma Nurses",
issn = "1078-7496",
publisher = "Lippincott Williams and Wilkins",
number = "1",

}

TY - JOUR

T1 - Decreasing radiation exposure in pediatric trauma related to cervical spine clearance

T2 - A quality improvement project

AU - Waddell, Valerie Ann

AU - Connelly, Susan

PY - 2018/1/1

Y1 - 2018/1/1

N2 - Study Design: Quality improvement project. Objectives: Reduce the amount of radiation exposure in the pediatric trauma population 5 years of age and older in relation to cervical spine clearance. Background: The evaluation of pediatric cervical spine injuries must be accurate and timely to avoid missed injuries. The difficult clinical examination in pediatric trauma patients necessitates the use of radiologic examinations to avoid missing catastrophic injuries. However, exposure to radiation at an early age increases the pediatric patients' risk of developing cancer (R. A. Kleinerman, 2006). Methods: A retrospective chart review was conducted to assess radiation exposure in pediatric patients requiring evaluation for cervical spine clearance. Surgical staff and emergency department physicians received education on the risks related to pediatric radiation exposure and information related to the institution's diagnostic trends for cervical spine clearance. An algorithm was then developed to assist with determining the necessary imaging study for cervical spine clearance. Radiation exposure was monitored following initial education and use of the algorithm to determine its effect on radiation exposure. Results: The retrospective chart review identified cervical spine computed tomography (CT) in 34%, with an average radiation exposure of 3.5 mSv. Following education and introduction of an algorithm, 18% of patients underwent CT for cervical spine clearance with an average radiation exposure of 3.2 mSv, representing a 47% decrease in the use of CT. Conclusion: Staff education and the use of an algorithm show promise in the reduction of radiation exposure and provide safe, effective clearance of the cervical spine in pediatric trauma.

AB - Study Design: Quality improvement project. Objectives: Reduce the amount of radiation exposure in the pediatric trauma population 5 years of age and older in relation to cervical spine clearance. Background: The evaluation of pediatric cervical spine injuries must be accurate and timely to avoid missed injuries. The difficult clinical examination in pediatric trauma patients necessitates the use of radiologic examinations to avoid missing catastrophic injuries. However, exposure to radiation at an early age increases the pediatric patients' risk of developing cancer (R. A. Kleinerman, 2006). Methods: A retrospective chart review was conducted to assess radiation exposure in pediatric patients requiring evaluation for cervical spine clearance. Surgical staff and emergency department physicians received education on the risks related to pediatric radiation exposure and information related to the institution's diagnostic trends for cervical spine clearance. An algorithm was then developed to assist with determining the necessary imaging study for cervical spine clearance. Radiation exposure was monitored following initial education and use of the algorithm to determine its effect on radiation exposure. Results: The retrospective chart review identified cervical spine computed tomography (CT) in 34%, with an average radiation exposure of 3.5 mSv. Following education and introduction of an algorithm, 18% of patients underwent CT for cervical spine clearance with an average radiation exposure of 3.2 mSv, representing a 47% decrease in the use of CT. Conclusion: Staff education and the use of an algorithm show promise in the reduction of radiation exposure and provide safe, effective clearance of the cervical spine in pediatric trauma.

UR - http://www.scopus.com/inward/record.url?scp=85051791317&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85051791317&partnerID=8YFLogxK

U2 - 10.1097/JTN.0000000000000340

DO - 10.1097/JTN.0000000000000340

M3 - Article

VL - 25

SP - 38

EP - 44

JO - Journal of trauma nursing : the official journal of the Society of Trauma Nurses

JF - Journal of trauma nursing : the official journal of the Society of Trauma Nurses

SN - 1078-7496

IS - 1