Influence of thermal stress on simulated localized and generalized wear of nanofilled resin composites

A. Tsujimoto, Wayne W. Barkmeier, T. Takamizawa, Mark A. Latta, M. Miyazaki

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Objective: This study investigated the influence of thermal stress on the simulated localized and generalized wear of nanofilled resin composites. Methods: Six nanofilled resin composites were evaluated and then subjected to a wear challenge of 400,000 cycles in a Leinfelder-Suzuki (Alabama) wear simulation device after 24 hours of water storage (24-hour group) and 24 hours of water storage and 10,000 thermal cycles (TC group). Simulated localized wear was generated using a stainless-steel ball bearing, and simulated generalized wear was generated using a flat-ended stainless-steel cylinder. Wear testing was accomplished in a water slurry of polymethyl methacrylate beads. Simulated localized and generalized wear was determined using a noncontact profilometer (Proscan 2100) in conjunction with Proscan and AnSur 3D software. Results: Wear was significantly different (p,<0.05) among the resin composites for both simulated localized and generalized wear of either the 24-hour group or the TC group. The simulated localized wear of the TC group was significantly greater than that of the 24-hour group; however, the simulated generalized wear of most of the resin composites of the TC group was not significantly different from that of the 24-hour group. Conclusion: The simulated localized and generalized wear of nanofilled resin composites is material dependent. The simulated localized wear of nanofilled resin composites appears to be influenced by thermal stress, whereas this effect is not as apparent in simulated generalized wear testing.

Original languageEnglish (US)
Pages (from-to)380-390
Number of pages11
JournalOperative Dentistry
Volume43
Issue number4
DOIs
StatePublished - Jul 1 2018

Fingerprint

Composite Resins
Hot Temperature
Stainless Steel
Water
Polymethyl Methacrylate
Software
Equipment and Supplies

All Science Journal Classification (ASJC) codes

  • Dentistry(all)

Cite this

Influence of thermal stress on simulated localized and generalized wear of nanofilled resin composites. / Tsujimoto, A.; Barkmeier, Wayne W.; Takamizawa, T.; Latta, Mark A.; Miyazaki, M.

In: Operative Dentistry, Vol. 43, No. 4, 01.07.2018, p. 380-390.

Research output: Contribution to journalArticle

@article{411b1290620a482c85a4945b52f6d639,
title = "Influence of thermal stress on simulated localized and generalized wear of nanofilled resin composites",
abstract = "Objective: This study investigated the influence of thermal stress on the simulated localized and generalized wear of nanofilled resin composites. Methods: Six nanofilled resin composites were evaluated and then subjected to a wear challenge of 400,000 cycles in a Leinfelder-Suzuki (Alabama) wear simulation device after 24 hours of water storage (24-hour group) and 24 hours of water storage and 10,000 thermal cycles (TC group). Simulated localized wear was generated using a stainless-steel ball bearing, and simulated generalized wear was generated using a flat-ended stainless-steel cylinder. Wear testing was accomplished in a water slurry of polymethyl methacrylate beads. Simulated localized and generalized wear was determined using a noncontact profilometer (Proscan 2100) in conjunction with Proscan and AnSur 3D software. Results: Wear was significantly different (p,<0.05) among the resin composites for both simulated localized and generalized wear of either the 24-hour group or the TC group. The simulated localized wear of the TC group was significantly greater than that of the 24-hour group; however, the simulated generalized wear of most of the resin composites of the TC group was not significantly different from that of the 24-hour group. Conclusion: The simulated localized and generalized wear of nanofilled resin composites is material dependent. The simulated localized wear of nanofilled resin composites appears to be influenced by thermal stress, whereas this effect is not as apparent in simulated generalized wear testing.",
author = "A. Tsujimoto and Barkmeier, {Wayne W.} and T. Takamizawa and Latta, {Mark A.} and M. Miyazaki",
year = "2018",
month = "7",
day = "1",
doi = "10.2341/16-206-L",
language = "English (US)",
volume = "43",
pages = "380--390",
journal = "Operative Dentistry",
issn = "0361-7734",
publisher = "Indiana University School of Dentistry",
number = "4",

}

TY - JOUR

T1 - Influence of thermal stress on simulated localized and generalized wear of nanofilled resin composites

AU - Tsujimoto, A.

AU - Barkmeier, Wayne W.

AU - Takamizawa, T.

AU - Latta, Mark A.

AU - Miyazaki, M.

PY - 2018/7/1

Y1 - 2018/7/1

N2 - Objective: This study investigated the influence of thermal stress on the simulated localized and generalized wear of nanofilled resin composites. Methods: Six nanofilled resin composites were evaluated and then subjected to a wear challenge of 400,000 cycles in a Leinfelder-Suzuki (Alabama) wear simulation device after 24 hours of water storage (24-hour group) and 24 hours of water storage and 10,000 thermal cycles (TC group). Simulated localized wear was generated using a stainless-steel ball bearing, and simulated generalized wear was generated using a flat-ended stainless-steel cylinder. Wear testing was accomplished in a water slurry of polymethyl methacrylate beads. Simulated localized and generalized wear was determined using a noncontact profilometer (Proscan 2100) in conjunction with Proscan and AnSur 3D software. Results: Wear was significantly different (p,<0.05) among the resin composites for both simulated localized and generalized wear of either the 24-hour group or the TC group. The simulated localized wear of the TC group was significantly greater than that of the 24-hour group; however, the simulated generalized wear of most of the resin composites of the TC group was not significantly different from that of the 24-hour group. Conclusion: The simulated localized and generalized wear of nanofilled resin composites is material dependent. The simulated localized wear of nanofilled resin composites appears to be influenced by thermal stress, whereas this effect is not as apparent in simulated generalized wear testing.

AB - Objective: This study investigated the influence of thermal stress on the simulated localized and generalized wear of nanofilled resin composites. Methods: Six nanofilled resin composites were evaluated and then subjected to a wear challenge of 400,000 cycles in a Leinfelder-Suzuki (Alabama) wear simulation device after 24 hours of water storage (24-hour group) and 24 hours of water storage and 10,000 thermal cycles (TC group). Simulated localized wear was generated using a stainless-steel ball bearing, and simulated generalized wear was generated using a flat-ended stainless-steel cylinder. Wear testing was accomplished in a water slurry of polymethyl methacrylate beads. Simulated localized and generalized wear was determined using a noncontact profilometer (Proscan 2100) in conjunction with Proscan and AnSur 3D software. Results: Wear was significantly different (p,<0.05) among the resin composites for both simulated localized and generalized wear of either the 24-hour group or the TC group. The simulated localized wear of the TC group was significantly greater than that of the 24-hour group; however, the simulated generalized wear of most of the resin composites of the TC group was not significantly different from that of the 24-hour group. Conclusion: The simulated localized and generalized wear of nanofilled resin composites is material dependent. The simulated localized wear of nanofilled resin composites appears to be influenced by thermal stress, whereas this effect is not as apparent in simulated generalized wear testing.

UR - http://www.scopus.com/inward/record.url?scp=85049588314&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85049588314&partnerID=8YFLogxK

U2 - 10.2341/16-206-L

DO - 10.2341/16-206-L

M3 - Article

VL - 43

SP - 380

EP - 390

JO - Operative Dentistry

JF - Operative Dentistry

SN - 0361-7734

IS - 4

ER -