Reliability of Center of Pressure Measures for Assessing the Development of Sitting Postural Control

Anastasia Kyvelidou, Regina T. Harbourne, Wayne A. Stuberg, Junfeng Sun, Nicholas Stergiou

Research output: Contribution to journalArticle

24 Citations (Scopus)

Abstract

Kyvelidou A, Harbourne RT, Stuberg WA, Sun J, Stergiou N. Reliability of center of pressure measures for assessing the development of sitting postural control. Objectives: To determine the reliability of linear and nonlinear tools, including intrasession and intersession reliability, when used to analyze the center of pressure (COP) time series during the development of infant sitting postural control. Design: Longitudinal study. Setting: University hospital laboratory. Participants: Typically developing infants (N=33; mean ± SD age at entry in the study, 152.4±17.6d). Interventions: Not applicable. Main Outcome Measures: Infants were tested twice in 1 week at each of the 4 months of the study. Sitting COP data were recorded for 3 trials at each session (2 each month within 1 week). The linear COP parameters of root mean square and range of sway for both the anterior-posterior and the medial-lateral directions, and the sway path, were calculated. The nonlinear parameters of approximate entropy, Lyapunov exponent, and correlation dimension for both directions were also calculated. Intrasession and intersession reliability was quantified by the intraclass correlation coefficient (ICC). Results: The nonlinear tool of approximate entropy presented high intrasession and intersession ICC values compared with all other parameters evaluated. Generally, intrasession and intersession reliability increased in the last 2 months of the data collection and as sitting posture matured. Conclusions: Our results showed that the evaluation of COP data is a reliable method of investigating the development of sitting postural control. The present study emphasizes the need for establishing COP reliability before using it as a method of examining intervention progress directed at improving the sitting postural abilities in infants with motor developmental delays.

Original languageEnglish (US)
Pages (from-to)1176-1184
Number of pages9
JournalArchives of Physical Medicine and Rehabilitation
Volume90
Issue number7
DOIs
StatePublished - Jul 1 2009
Externally publishedYes

Fingerprint

Pressure
Entropy
Hospital Laboratories
Aptitude
Solar System
Child Development
Posture
Longitudinal Studies
Outcome Assessment (Health Care)
Direction compound

All Science Journal Classification (ASJC) codes

  • Physical Therapy, Sports Therapy and Rehabilitation
  • Rehabilitation

Cite this

Reliability of Center of Pressure Measures for Assessing the Development of Sitting Postural Control. / Kyvelidou, Anastasia; Harbourne, Regina T.; Stuberg, Wayne A.; Sun, Junfeng; Stergiou, Nicholas.

In: Archives of Physical Medicine and Rehabilitation, Vol. 90, No. 7, 01.07.2009, p. 1176-1184.

Research output: Contribution to journalArticle

Kyvelidou, Anastasia ; Harbourne, Regina T. ; Stuberg, Wayne A. ; Sun, Junfeng ; Stergiou, Nicholas. / Reliability of Center of Pressure Measures for Assessing the Development of Sitting Postural Control. In: Archives of Physical Medicine and Rehabilitation. 2009 ; Vol. 90, No. 7. pp. 1176-1184.
@article{f6f892ca2fe94c659a48dd6c6339625c,
title = "Reliability of Center of Pressure Measures for Assessing the Development of Sitting Postural Control",
abstract = "Kyvelidou A, Harbourne RT, Stuberg WA, Sun J, Stergiou N. Reliability of center of pressure measures for assessing the development of sitting postural control. Objectives: To determine the reliability of linear and nonlinear tools, including intrasession and intersession reliability, when used to analyze the center of pressure (COP) time series during the development of infant sitting postural control. Design: Longitudinal study. Setting: University hospital laboratory. Participants: Typically developing infants (N=33; mean ± SD age at entry in the study, 152.4±17.6d). Interventions: Not applicable. Main Outcome Measures: Infants were tested twice in 1 week at each of the 4 months of the study. Sitting COP data were recorded for 3 trials at each session (2 each month within 1 week). The linear COP parameters of root mean square and range of sway for both the anterior-posterior and the medial-lateral directions, and the sway path, were calculated. The nonlinear parameters of approximate entropy, Lyapunov exponent, and correlation dimension for both directions were also calculated. Intrasession and intersession reliability was quantified by the intraclass correlation coefficient (ICC). Results: The nonlinear tool of approximate entropy presented high intrasession and intersession ICC values compared with all other parameters evaluated. Generally, intrasession and intersession reliability increased in the last 2 months of the data collection and as sitting posture matured. Conclusions: Our results showed that the evaluation of COP data is a reliable method of investigating the development of sitting postural control. The present study emphasizes the need for establishing COP reliability before using it as a method of examining intervention progress directed at improving the sitting postural abilities in infants with motor developmental delays.",
author = "Anastasia Kyvelidou and Harbourne, {Regina T.} and Stuberg, {Wayne A.} and Junfeng Sun and Nicholas Stergiou",
year = "2009",
month = "7",
day = "1",
doi = "10.1016/j.apmr.2009.01.031",
language = "English (US)",
volume = "90",
pages = "1176--1184",
journal = "Archives of Physical Medicine and Rehabilitation",
issn = "0003-9993",
publisher = "W.B. Saunders Ltd",
number = "7",

}

TY - JOUR

T1 - Reliability of Center of Pressure Measures for Assessing the Development of Sitting Postural Control

AU - Kyvelidou, Anastasia

AU - Harbourne, Regina T.

AU - Stuberg, Wayne A.

AU - Sun, Junfeng

AU - Stergiou, Nicholas

PY - 2009/7/1

Y1 - 2009/7/1

N2 - Kyvelidou A, Harbourne RT, Stuberg WA, Sun J, Stergiou N. Reliability of center of pressure measures for assessing the development of sitting postural control. Objectives: To determine the reliability of linear and nonlinear tools, including intrasession and intersession reliability, when used to analyze the center of pressure (COP) time series during the development of infant sitting postural control. Design: Longitudinal study. Setting: University hospital laboratory. Participants: Typically developing infants (N=33; mean ± SD age at entry in the study, 152.4±17.6d). Interventions: Not applicable. Main Outcome Measures: Infants were tested twice in 1 week at each of the 4 months of the study. Sitting COP data were recorded for 3 trials at each session (2 each month within 1 week). The linear COP parameters of root mean square and range of sway for both the anterior-posterior and the medial-lateral directions, and the sway path, were calculated. The nonlinear parameters of approximate entropy, Lyapunov exponent, and correlation dimension for both directions were also calculated. Intrasession and intersession reliability was quantified by the intraclass correlation coefficient (ICC). Results: The nonlinear tool of approximate entropy presented high intrasession and intersession ICC values compared with all other parameters evaluated. Generally, intrasession and intersession reliability increased in the last 2 months of the data collection and as sitting posture matured. Conclusions: Our results showed that the evaluation of COP data is a reliable method of investigating the development of sitting postural control. The present study emphasizes the need for establishing COP reliability before using it as a method of examining intervention progress directed at improving the sitting postural abilities in infants with motor developmental delays.

AB - Kyvelidou A, Harbourne RT, Stuberg WA, Sun J, Stergiou N. Reliability of center of pressure measures for assessing the development of sitting postural control. Objectives: To determine the reliability of linear and nonlinear tools, including intrasession and intersession reliability, when used to analyze the center of pressure (COP) time series during the development of infant sitting postural control. Design: Longitudinal study. Setting: University hospital laboratory. Participants: Typically developing infants (N=33; mean ± SD age at entry in the study, 152.4±17.6d). Interventions: Not applicable. Main Outcome Measures: Infants were tested twice in 1 week at each of the 4 months of the study. Sitting COP data were recorded for 3 trials at each session (2 each month within 1 week). The linear COP parameters of root mean square and range of sway for both the anterior-posterior and the medial-lateral directions, and the sway path, were calculated. The nonlinear parameters of approximate entropy, Lyapunov exponent, and correlation dimension for both directions were also calculated. Intrasession and intersession reliability was quantified by the intraclass correlation coefficient (ICC). Results: The nonlinear tool of approximate entropy presented high intrasession and intersession ICC values compared with all other parameters evaluated. Generally, intrasession and intersession reliability increased in the last 2 months of the data collection and as sitting posture matured. Conclusions: Our results showed that the evaluation of COP data is a reliable method of investigating the development of sitting postural control. The present study emphasizes the need for establishing COP reliability before using it as a method of examining intervention progress directed at improving the sitting postural abilities in infants with motor developmental delays.

UR - http://www.scopus.com/inward/record.url?scp=67649389470&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=67649389470&partnerID=8YFLogxK

U2 - 10.1016/j.apmr.2009.01.031

DO - 10.1016/j.apmr.2009.01.031

M3 - Article

VL - 90

SP - 1176

EP - 1184

JO - Archives of Physical Medicine and Rehabilitation

JF - Archives of Physical Medicine and Rehabilitation

SN - 0003-9993

IS - 7

ER -